TTN 2015 PWM CY30A Solar Charge Controller
Delivery term:The date of payment from buyers deliver within days-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Beijing
-
Validity to:
Long-term effective
-
Last update:
2017-12-25 18:41
-
Browse the number:
97
+
Zhejiang TTN Electric Co. Ltd
- Contactaixin:
Contactaixin:
ttn(Mr.)
- telephone:
-
Area:
Beijing
Address:No. 28 Chuangda Road, Lucheng LightIndustrial Zone, Wenzhou, Zhejiang, China (325000)
- Website:
+
Model Number: TTN-CY30A
Brand Name: TTN
Key Specifications/Special Features:
Product IntroductionThe CM/CY series charge controllers is the highlight in the range.Use of the latest charging technologies combined with state of charge determination enable optimal battery maintenance and module power monitoring for up to 2880 Wp of connected power. A large display informs the user about all operating modes with the aid of symbols. The state of charge is represented visually in the form of a tank display. Data such as voltage, current and state of charge can also be displayed digitally as figures on the display.4Integrated data logger energy meter4Automatic detection of voltage4PWM control4Multistage charging technology4Automatic load reconnection
4Temperature compensation
4Overcharge protection
4Deep discharge protection
4Reverse polarity protection
Short circuit protection of load
Reverse current protection at night
Load disconnection on battery overvoltage
Installation
Only install the regulator near the battery on a suitable surface. This surface should be solid, stabile, even, dry and nonflammable. The battery cable should be as short as possible and have a suitable cable diameter size to minimize loss, e.g. 4 mm at 20 A and 2m length.
If the solar battery will be operated under a large temperature range (winter/summer) the external temperature sensor should be used. A temperature compensated final charge voltage will extend the batteries lifetime and uses the optimum charge capacity.
Do not install the controller to direct sunlight.
To ensure the air confection on each side keep a distance of 10 cm to the regulator. The temperature at the installation site may never fall below or exceed the maximal permitted ambient temperature.
Connect the individual components to the symbols provided.
Observe the following connection sequence during commissioning:
1. Connect the battery to the charge regulator - plus and minus
2. Connect the photovoltaic module to the charge regulator - plus and minus
3. Connect the consumer to the charge regulator - plus and minus
The reverse order applies when deinstalling!
Please observe that the automatic adjustment to 12V/24V systems does not function properly,if this sequence order is not followed. An improper sequence order can damage the battery!
4Temperature compensation
4Overcharge protection
4Deep discharge protection
4Reverse polarity protection
Short circuit protection of load
Reverse current protection at night
Load disconnection on battery overvoltage
Installation
Only install the regulator near the battery on a suitable surface. This surface should be solid, stabile, even, dry and nonflammable. The battery cable should be as short as possible and have a suitable cable diameter size to minimize loss, e.g. 4 mm at 20 A and 2m length.
If the solar battery will be operated under a large temperature range (winter/summer) the external temperature sensor should be used. A temperature compensated final charge voltage will extend the batteries lifetime and uses the optimum charge capacity.
Do not install the controller to direct sunlight.
To ensure the air confection on each side keep a distance of 10 cm to the regulator. The temperature at the installation site may never fall below or exceed the maximal permitted ambient temperature.
Connect the individual components to the symbols provided.
Observe the following connection sequence during commissioning:
1. Connect the battery to the charge regulator - plus and minus
2. Connect the photovoltaic module to the charge regulator - plus and minus
3. Connect the consumer to the charge regulator - plus and minus
The reverse order applies when deinstalling!
Please observe that the automatic adjustment to 12V/24V systems does not function properly,if this sequence order is not followed. An improper sequence order can damage the battery!
Model | CM3024 CY30A-24 |
CM5024 CY50A-24 |
CM3048 CY30A-48 |
CM5048 CY50A-48 |
CM6024 CY60A-24 |
CM6048 CY60A-48 |
Rated current | 30A | 50A | 30A | 50A | 60A | 60A |
Rated voltage | 12/24V | 12/24V | 48V | 48V | 12/24V | 48V |
Max solar voltage | <50V | <50V | <100V | <100V | <50V | <100V |
Low voltage disconnect | 10.7/21.4V | 42.8V 50.4V 54.8V |
10.7/21.4V | 42.8V | ||
Low voltage disconnect | 12.6/25.2V | 12.6/25.2V | 50.4V | |||
Float charge | 13.7/27.4V | 13.7/27.4V | 54.8V | |||
Standby loss | 54.8V | |||||
Charging mode | PWM | |||||
Temp compensation | -4mV/Cell/℃ | |||||
Opearating condition | -20℃~+60℃ | |||||
Size/Weight | CM3024 | 90x188x48 360g |
CY30A-24 | 110*170*55 300g |
||
CM3048 | CY30A-48 | |||||
CM5024 | 130x188x62 590g |
CY50A-24 | 130x188x62 570g |
|||
CM6024 | CY50A-48 | |||||
CM5048 | CY60A-24 | |||||
CM6048 | CY60A-48 |
Shipping Information:
- FOB Port: Ningbo
- Lead Time: 15 - 25 days
Main Export Markets:
- Asia
- Eastern Europe
- Mid East/Africa